Powerward
Three Phase ESS Hybrid Inverter
01
- ● With island protection, PV reverse polarity protection, battery reverse polarity protection,insulation monitoring, residual current monitoring, AC over current protection, AC over power protection, short circuit protection.
- ● It is more economical to support multiple operating modes;
- ● Can be as a UPS for the important loads when power off.
- ● Less noise: no cooling system needed.
- ● Diesel generator supported.
- ● Support full power discharge, automatic management of battery charge and discharge.
Mechanical parameters
- Dimensions(W*H*D): 530*560*220mm
- Weight: 30kg; 30kg; 31kg; 32kg; 34kg
Battery
- Discharging Power: 6600W/8800W/11000W/13200W/16500W
- Working Voltage Range: 150-550V
- Discharging Current: 50A
- Battery Type: Lithium and Lead Acid Battery
Input DC (PV)
- Max pv input power: 9000W/12000W/15000W/18000W/22500W
- MPPT voltage range: 180-850V
- Full power MPPT voltage range: 250V-850V; 330V-850V; 430V-850V; 510V-850V; 620V-850V
- Start-up voltage: 125V
- Max.input current per MPPT: 13/13A; 13/13A; 13/13A; 13/13A; 20/20A
- Max. Short-circuit current: 16/16A; 16/16A; 16/16A; 16/16A; 30/30A
- Number of MPP trackers: 2
- Rated input voltage: 600V
AC Output data (On-Grid)
- Nominal output power to grid: 6000VA/8000VA/10000VA/12000VA/15000VA
- Max. Apparent power to grid: 6600W/8800W/11000W/13200W/16500W
- Max. Apparent power from grid: 13200VA/17600VA/22000VA/26400VA/33000VA
- Nominal grid voltage: 380V/400V,3W+N+PE
- Nominal grid frequency: 50Hz/60Hz
- THDI: <2%
AC Output data (Back Up)
- Nominal output power: 8000VA/8000VA/10000VA/12000VA/15000VA
- Max. Apparent power: 88008800110001320016500
- Max.output current: 9.5A/12.7A/15.9A/19.1A/23.8A
- Nominal output voltage: 400V,3W+N+PE
- Nominal output frequency: 50Hz/60Hz
- THDu: <2%
- Max.efficiency: 97.9%/97.9%/98.2%/98.2%/98.5%
- Europe efficiency: 97.2%/97.2%/97.5%/97.5%/97.6%
General data
- Ingress protection: IP65
- Operating temperature range: -35-60°C
- Relative humidity: 0-100%
- Operating altitude: 4000m(Derating above 2000 m)
- Cooling: Natural convection
- Noise emission: ≤25dB
- Installation: Wall mounted
- Emc: IEC/EN 61000-6-1:2019, IEC/EN 61000-6-2:2019, IEC/EN 61000-6-3:2021, IEN/EN61000-6-4:2019, IEC/EN 61000-3-2:2019/A1:2021, EN 61000-3-3:2013/A2:2021.\, IEC/EN61000-3-11:2019, EN61000-3-12:2011
Grid Regulation
- Europe: EN 50549-1:2019/AC:2019
- Poland:EN50549-1:2019/Rfg:2016/NC Rfg:2018/PTPiREE:2021
- Germany: VDE-AR-N 4105:2018/DIN VDEV0124-100(VDEV 0124-100):2020
- South Africa: NRS 097-2-1:2017 Edition 2.1
- UK: G99/ 1-6 : 2020 Spain : UNE217001 : 2020/ UNE217002 : 2020/ NTSV2.1 : 2021071EC61727 : 2004/ 1EC62116 : 2014/ 1EC61683 : 1999
- Hungary: EN50549-1:2019/ RFG:2016/ Hungary
- Safety regulation: IEC/ EN62109-1:2010, IEC/ EN62109-2:2011
Note: the product continues to innovate and the performance continues to improve. This parameter description is for reference only.
-
Powerward Three Phase ESS Hybrid Inverter-Datasheet
Download